Low temperature strategy
For parts that are sensitive to temperature requirements, components that can be stored and operated at low temperatures are preferred.
There is a heating device in the control box of the brake, and the temperature is automatically controlled. When the ambient temperature is lower than the set temperature (5 °C), the heating device will automatically start, the temperature of the machine processing; When the temperature rises to 25 °C, the automatic stop heating, to ensure that the working temperature in the 5 °C ~ 25 °C constant temperature range.
High temperature strategy
High-temperature-resistant materials, modules and accessories are used. For example, the display of the switchgear can be stored at 70°C and operated at 60°C.
In addition, in order to meet the equipment can work at 60 °C, the device also has a cooling design:
Electrical design of the equipment adopts low power consumption design;
Through the addition of semiconductor cooling plates, the heat generated by the higher-heating components is conducted to the chassis and the heat is dissipated through the chassis;
For components with high heat such as power supply and main control board, install cooling fans and other cooling measures.
Lightning protection strategy
The interior of the gate is equipped with power supply lightning protection and network lightning protection dual lightning protection devices.
The lightning protection of the power supply can effectively block the lightning current introduced through the power network and ensure that the internal electrical equipment is not damaged.