The constant temperature and humidity chamber is a test box device equipped with many laboratories. After being put into operation, it is often uninterrupted. As an electrical equipment, the operation of the constant temperature and humidity chamber is highly dependent on electrical energy. Therefore, how to save energy and save electricity is also a problem to be considered in the laboratory management process. Below we can analyze the reasons for the power consumption of the constant temperature and humidity chamber from several dimensions. At the same time, for different situations, how do you save energy and save energy in a long-term constant temperature and humidity chamber? 1. Placement: The constant temperature and humidity test chamber should be placed in a cool and ventilated place, avoid direct sunlight, keep away from heat sources, and leave appropriate space on the left and right sides and back of the constant temperature and humidity test chamber when placing. Cooling. Because the high ambient temperature around the constant temperature and humidity test chamber will increase the power consumption of the test chamber. 2. Always check the tightness of the seal of the constant temperature and humidity test chamber. If the seal is deformed, it will affect the degree of tightness of the closed joint, resulting in leakage of cold air, thus increasing power consumption. If the deformation is serious, it should be repaired and replaced in time. 3. After using the constant temperature and humidity test chamber for a period of time, some frost will be generated. If it cannot be tempered regularly, it will affect the cooling effect, and the power consumption will increase, and it may even damage the compressor. Therefore, whenever the thickness of the frost is seen to exceed 7 cm, defrosting should be performed. 4. Whenever you open the door, you will have cold air and heat intrusion, so you must run the compressor again. Therefore, when accessing the sample, it is necessary to minimize the number of door opening and door opening time, and to open and close the door faster, and the opening angle should be as small as possible. The use and maintenance of the constant temperature and humidity chamber in the correct way is the key “password†for energy saving and energy saving in the constant temperature and humidity chamber. Doing these tasks and realizing the “low-carbon†operation of the equipment not only helps to reduce the operating costs of the laboratory, but also meets the needs of modern people and can make our lives better. Cold drawn, Peeled or Turned Ground and Polished Steel Bar
Peeled or turned steel bar is produced by peeling or turning from Hot Rolled Steel Bar. Our advantages and more services of Cold Drawn Steel Round Bar includes:
1) Wide range of diameters from 20mm to 150mm
2) Customized Length from 100mm to 12000mm
3) Good surface roughness: 0.4um to 1.6um
4) Good straightness: 0.5mm/m to 2mm/m
5) Good roundness: 80% of diameter tolerance
6) Diameter tolerance: -0.02mm to -0.1mm / h9, h10, h11
7) Matched further processing: Grinding, polishing, straightening
8) Anti-rusty package
9) Full sets of testing equipment: Surface, Dimenstion. Mechanical properties testing
10) Fast delivery time
Turned and polished Steel Bar,Turned Ground and Polished Steel Round Bar,Centerless Ground Shat,Ground and Polished Round Steel Bar, Peeled Ground and Polished Round Steel Bar SHANDONG LE REN SPECIAL STEEL CO., LTD. , https://www.js-luggagecarts.com
5, always pay attention to the constant temperature and humidity test chamber "bath", the surface of the compressor and condenser should be cleaned every two to three months, the more dust, the worse the heat dissipation effect, the greater the power consumption, cleaning Turn off the power and wipe it off with a damp cloth.