Feature: Fixing Foam,Fire Rated Pu Foam,Pu Foam Adhesive,Pu Foam Waterproof Hunan Magpow Adhesive Group co.,ltd , https://www.magicglue.net
This product combined the functions of heat insulation, cold insulation, moisture-proof, quakeproof, insulation, sealing, seal, heat preservation, cementation together,with the characteristics of high foaming quantity, the flexibility good, the cementation intensity high, characteristics and so on .It is the modern most ideal new building material, has the environmental protection energy conservation, construction convenience
Scope of application:
Windows and doors installment: Between windows and doors and wall sealing seal, fixed caking.
Advertisement model: The model, the sand table manufacture, unfolds board patching.
Sound-insulated noise elimination: Repair and so on the time language sound chamber, broadcast studio slit fills, may play the sound-insulated noise elimination role.
The gardening makes the scenery: Flower arrangement, slit, wall brick, brick, floor patching.
Guards against the water blocking to leak: Loophole and so on water conduct, sewer patching, stop up originally leak.
Packing and transportation: Prevent the expensive the fragile goods from broken, time saving and fast, earthquake durable.
Using Method:
1. 3-5 hour.
2. Before the use, sways the hoisting bucket fully (at least 20 times), guarantees in the pot the material to be even.
3.If uses the gun type froth sealing medicinal preparation, when use the hoisting bucket inversion and the spray gun screw joint, revolving opens the flow valve, after the adjustment current capacity carries on again spraying.
4. When spraying pays attention to the approaching speed, usually sprays the quantity to have to fill the volume one half then. Filled when the vertical slit when should from bottom to top, on the packing such as ceiling slit, as a result of the gravity function, the solidification froth possibly has not been able to fall, after suggested just filled carries on the suitable support, treated the froth solidification and evacuates the support again after the seam wall caking.
5. About 10 minutes, the froth skin drying, after 1 hour the froth solidifies approximately, and the froth achieves the best load-bearing effect stably in g.
6. Slices the extra amount froth with the knife, then in superficial water used soil mortar, coating or silica gel .Before the construction, should remove the greasy dirt and the floating dust from the surface, and sprays the few water in the construction surface, causes its moistly
7. the use finished, takes down the hoisting bucket, cleans cleanly with the special-purpose cleansing agent the spray gun
Heat pump is high in the energy of the drag, the heat flow from low to high heat source technology. It can convert low-grade heat energy (such as air, soil, water, solar energy, industrial waste heat, etc.) that can not be directly used into the available high energy so as to save some high energy (coal, oil, natural gas, electricity, etc.) . The use of low-energy heat pump technology can save fuel, rational use of energy, reduce environmental pollution, as an energy saving and environmental protection both ways. Some studies show that compared with the energy consumption of the regional boiler house, the energy consumption of the heat pump station of the same capacity is as follows: when the river water (5 ~ 6.6 ℃) is used as the low-level heat source, the annual coal-saving rate is 12.68-14.08% 13.6 ℃) as low-level heat source, annual coal-saving rate was 21.59-39.98%. When using industrial wastewater (18-20 ℃) ​​as low-level heat source, the annual coal-saving rate was 39-39.98%. The efficiency of the heat pump is related to the temperature difference between the indoor and outdoor environment of the building. The smaller the temperature difference, the higher the heat pump efficiency. Some researches show that the use of air source heat pump is not only related to the outdoor temperature, but also closely related to the relative humidity of the outdoor air, which greatly limits the scope of its use from the perspective of defrosting the heat pump unit during winter operation. With ground-source heat pump systems, ground-source heat pumps are more efficient and dependable than air-source heat pumps because they are reasonably well-designed because the temperature of the soil is closer to the indoor temperature than outdoor air. In addition, because the same volume flow rate of water heat capacity is 3500 times the air, water and refrigerant heat transfer effect is much better than the air and refrigerant convection heat transfer, so the ground source heat pump heat exchanger coil than the air source heat pump Much smaller and less ground-source heat pump system components to reduce operating costs.