1. Magnetic pump bearings cooling and lubrication is transported by the media, it is absolutely forbidden air-to-run, while avoiding the middle of the work after the restart caused by space-time load operation.

2 is transported medium, if it contains solid particles, the pump inlet to be added to the filter: If containing ferromagnetic particles, the need to add magnetic filters.

3. Pump in use should be less than 40 ℃ ambient temperature, motor temperature must not exceed 75 ℃.

4. The medium being conveyed and its temperature should be within the allowable range of the pump. Engineering plastics pump temperature <60 ℃, metal pump temperature <100 ℃, conveying suction pressure is not more than 0.2MPa, the maximum working pressure 1.6MPa, the density of not more than 1600Kg / m3, the viscosity is not more than 30X10-6m2 / S Liquids containing hard particles and fibers.

5. For the transmission fluid is easy to precipitate crystallization of the media, after use should be promptly cleaned, drain the pump fluid.

6. 1000 hours after the normal operation of the magnetic pump should be demolished inspection bearing and face ring wear and tear, and replace the consumable parts should not be reused.